Add to Cart
Q195 Q215 Q235 Q345 Structural ERW Carbon Steel Pipe
Structural ERW Carbon Steel Pipe Use In Various Engineering Purposes, Fencing, Scaffolding Etc
Both electric resistance welded (ERW) and submerged arc welded (SAW) tube or pipe is mostly produced by first forming steel sheet or plate into a cylinder and then welding the longitudinal gap to form a seam.
With ERW the seam is progressively welded using a combination of heat and pressure. Resistance to electric current generates heat in the weld locality, taking the temperature of the steel to just below its melting point. Simultaneously, mill rolls located around the pipe force the two edges of the formed sheet/plate together to join them.
Steel structure, with its own advantages, in the construction of the proportion is more and more big, the steel structure is also made great breakthrough. Steel tube structures with its unique advantages to get the favour of people, is mainly used in some large public buildings;In industrial workshop column and roof truss, light steel structure and potential application of residential steel structure is very wide;Such as Bridges, DAMS, offshore platform bearing with columns, large span steel structure building structure and electric tower mast structure has broad prospects.
ERW :Electric Resistance Welded pipe
Out Diameter:114.3mm - 812.8mm (4"-32")
Wall Thk:4mm-22mm
Length:3M-18M
Standard:API 5L, ASTM A500, ASTM A252, ASTM 53, EN10217, DIN 2458, IS 3589, JIS G3452, BS1387
Certificate:ISO 9001, ISO 14001, OHSAS 18001, API 5L PSL1&PSL2, CE (CPR & PED), GOST Certificates
Usage:Used for construction field, , in various engineering purposes, fencing, scaffolding etc.
Steel Grade:API 5L PSL1 & PSL2: GR B, X42, X46, X56, X60, X65, X70
ASTM A53: GR.A, GR.B
EN10210/EN10219: S275, S275JR, S355JRH, S355J2H
GB/T3091: Q195, Q215, Q235, Q345
Surface:Fusion bond Epoxy coating, Coal Tar Epoxy, 3PE, Vanish Coating, Bitumen Coating, Black Oil coating as per customer’s requirement
Tests:Chemical Component Analysis, Mechanical Properties (Ultimate tensile strength, Yield strength, Elongation), Technical Properties (Flattening Test, Bending Test, Blow Test, Impact Test), Exterior Size Inspection, Hydrostatic Test.
MTC:EN 10204/3.1B, EN 10204/3.2 (with Third Party Inspection
Size & Thickness:
Dimension | Wall Thickness | |||||||||||||||||
mm | 3.99 | 4.78 | 6.02 | 6.35 | 7.11 | 7.92 | 8.74 | 9.53 | 10.31 | 11.13 | 11.91 | 12.70 | 14.27 | 15.88 | 17.48 | 19.05 | 20.62 | |
inch | 0.157 | 0.188 | 0.237 | 0.250 | 0.280 | 0.312 | 0.344 | 0.375 | 0.406 | 0.438 | 0.469 | 0.500 | 0.562 | 0.625 | 0.688 | 0.750 | 0.812 | |
4 | 114.3 | |||||||||||||||||
6 | 168.3 | |||||||||||||||||
8 | 219.1 | |||||||||||||||||
10 | 273.1 | |||||||||||||||||
12 | 323.8 | |||||||||||||||||
14 | 355.6 | |||||||||||||||||
16 | 406.4 | |||||||||||||||||
18 | 457.2 | |||||||||||||||||
20 | 508 | |||||||||||||||||
22 | 558.8 | |||||||||||||||||
24 | 609.6 | |||||||||||||||||
26 | 660.4 | |||||||||||||||||
28 | 711.2 | |||||||||||||||||
32 | 812.8 |